- Color & Coating
- Environmental Testing Systems
- Temperature Humidity Chamber
- Ozone , Dust , Rain & Noxious Gas Chamber
- Accelerated Weathering Test Chamber
- Salt Spray Test Chamber
- Drying Oven
- Digital Thermometer
- Digital Temperature & Humidity Meter
- Infrared Thermometer
- Moisture Meter
- Anemometer
- Light Meter
- Sound Level Meter
- Particle Counter
- Vibration Machine
- Gas Detector
- Heater
- Others
- View All
- Material Testing
- Universal Testing Machine
- Charpy Pendulum Impact Tester
- BenchTop Hardness Tester
- Ultrasonic Thickness Gauge
- Portable Hardness Tester
- Shore Rubber & Plastic Hardness Tester
- Surface Roughness Tester
- Ultrasonic Flaw Detector
- Melt Flow Rate Meter (MFI)
- Sample Preparation Machine
- Asphalt & Bitument Testing
- Heat Stress Metter
- Precise Measurement Solution Provider
- Rheometer
- View All
- Metrology Measuring System
- Portable Measuring & Testing Instruments
- Weighing & Metal Detection System
- Electronic & Electrical Testing Equipments
- Lab & Scientific Equipments
- Equipments for Food & Beverage Packaging
- Hot Wire Bottle Cutter
- Vacuum Leak Tester
- Pressure or Vacuum Gauge
- Secure Seal Analyzer
- CO2 Easy / CO2 Easy-DCO2 Measuring Device
- Burn Test
- Can And End Testing Equipments
- CO2 Measure
- Crown Cap Measure & Test
- Cutting Packaging
- Dimensional Measure
- Filtering
- Force Measure/Compresion/Dynamometers
- Stress Aplication
- Torque Measure
- Others
- View All
- Electric Vehicle Equipment
- Ion Fan
- Microscope
- Service Maintenance & Calibration
- Others
Redmark Industry Sdn Bhd
141-2, Jalan Radin Bagus, Bandar Baru Sri Petaling, 57000 Kuala Lumpur, Malaysia.
+6012-499 2103
Redmark Industry (Penang)
Sdn Bhd
7206, Mez Floor, Kompleks Perniagaan Pangsapuri Seri Cemerlang, Jalan Kampung Paya, Kampung Paya, 12200 Butterworth, Penang, Malaysia.
chuin@redmarkindustry.com
Particle Counter/ Dust Monitor PCE-CPC 50
Previous | 1 / 38 | Next |
Particle Counter for fixed installation / Modbus and RJ45 interface / analogue outputs 4 ... 20 mA for 4 measuring channels
The state-of-the-art particle counter enables precise real-time measurement in the range from 0.3 μm to 10 μm to provide a comprehensive picture of the air quality. The results are presented in two units, either in number per m³, number per litre or number per 28.3l. Air sampling is performed by an internal pump. When the particles pass the light source (laser), light scattering occurs; the scattered light is converted into an electrical signal (pulse) by a photoelectric transducer, and the larger the particles, the larger the pulse signal.
The integration of Modbus and MQTT ensures seamless integration into existing networks and enables efficient data communication. The sampling time can be set from 1 to 10 min and the pause time from 1 to 1000 min. This function makes it possible to continuously monitor the cleanliness level and ensure that the premises meet the required standards.
Specification
Particles | |
Measuring range | 0 pcs/l ... 10000000 pcs/l |
Measurement channel sizes | 0.3, 0.5, 1.0, 2.5, 5.0, 10 µm |
Counting efficiency |
Less than 100 pcs/l: ±30 pcs/l Greater than 100 pcs/l: ±30 % of the weight at 0 ... 40 °C / 60 % r.h. |
Flow rate | 2.83 l/min |
General technical data | |
Analogue output | 4 ... 20 mA |
Interface | RS485, Ethernet |
Sensor | Laser scattered light |
Response time | 8 s |
Menu language | English, Chinese |
Protection class (device) | IP30 |
Power supply | 12 VDC |
Plug type | Protective contact plug |
Weight | 1293 g |
Depth | 87 mm |
Operating conditions | -30 ... 70 °C , 0 ... 95 % r.H |
Storage conditions | -40 ... 85 °C , 0 ... 95 % r.H |
Dust monitor for fixed installation / Modbus and RJ45 interface / analogue outputs 4 ... 20 mA for 4 measuring channels
The state-of-the-art dust monitor enables precise real-time measurement in the range from 0.3 μm to 10 μm to provide a comprehensive picture of the air quality. The results are presented in two units, either in number per m³, number per litre or number per 28.3l. Air sampling is performed by an internal pump. When the particles pass the light source (laser), light scattering occurs; the scattered light is converted into an electrical signal (pulse) by a photoelectric transducer, and the larger the particles, the larger the pulse signal.
The integration of Modbus and MQTT ensures seamless integration into existing networks and enables efficient data communication. The sampling time can be set from 1 to 10 min and the pause time from 1 to 1000 min. This function makes it possible to continuously monitor the cleanliness level and ensure that the premises meet the required standards.
Highlight
Specification
Particles | |
Measuring range | 0 pcs/l ... 10000000 pcs/l |
Measurement channel sizes | 0.3, 0.5, 1.0, 2.5, 5.0, 10 µm |
Counting efficiency |
Less than 100 pcs/l: ±30 pcs/l Greater than 100 pcs/l: ±30 % of the weight at 0 ... 40 °C / 60 % r.h. |
Flow rate | 2.83 l/min |
General technical data | |
Analogue output | 4 ... 20 mA |
Interface | RS485, Ethernet |
Sensor | Laser scattered light |
Response time | 8 s |
Menu language | English, Chinese |
Protection class (device) | IP30 |
Power supply | 12 VDC |
Plug type | Protective contact plug |
Weight | 1293 g |
Depth | 87 mm |
Operating conditions | -30 ... 70 °C , 0 ... 95 % r.H |
Storage conditions | -40 ... 85 °C , 0 ... 95 % r.H |
Delivery Scope